4-9
3. Configure IP address of SNMP management base
4. Configure engine ID
5. Configure user
6. Configure group
7. Configure view
8. Configuring TRAP
9. Enable/Disable RMON
1. Enable or disable SNMP Agent server function
snmp-server enabled
no snmp-server enabled
Enable the SNMP Agent function on the switch; the
no command disables the SNMP Agent function on
2. Configure SNMP community string
snmp-server community {ro|rw} <string>
[access {<num-std>|<name>}]
[ipv6-access
{<ipv6-num-std>|<ipv6-name>}] [read
<read-view-name>] [write
<write-view-name>]
no snmp-server community <string>
[access {<num-std>|<name>}]
[ipv6-access
{<ipv6-num-std>|<ipv6-name>}]
Configure the community string for the switch; the no
command deletes the configured community string.
3. Configure IP address of SNMP management base
snmp-server securityip { <ipv4-addr> |
<ipv6-addr> }
no snmp-server securityip { <ipv4-addr> |
Configure the secure IPv4/IPv6
allowed to access the switch on the NMS; the no
command deletes configured secure address.
snmp-server securityip enable
snmp-server securityip disable
Enable or disable secure IP address check function
4. Configure engine ID
Comments to this Manuals