Scenario 3: NMS uses SNMP v3 to obtain information from the switch.
The configuration on the switch is listed below:
Switch(config)#snmp
-server
Switch
(config)#snmp-server user tester UserGroup authPriv auth md5 hellotst
Switch
(config)#snmp-server group UserGroup AuthPriv read max write max notify max
Switch(config)#snmp-server view max 1 include
Scenario 4: NMS wants to receive the v3Trap messages sent by the switch.
The configuration on the switch is listed below:
Switch(config)#snmp
-server enable
Switch(config)#snmp
-server host 10.1.1.2 v3 authpriv tester
Switch(config)#snmp-server enable traps
Scenario 5: The IPv6 address of the NMS is 2004:1:2:3::2; the IPv6 address of the switch (Agent) is
2004:1:2:3::1. The NMS network administrative software uses SNMP protocol to obtain data from the switch.
The configuration on the switch is listed below:
Switch(config)#snmp
-server enable
Switch(config)#snmp
-server community rw private
Switch(config)#snmp
-server community ro public
Switch(config)#snmp-server securityip 2004:1:2:3::2
The NMS can use private as the community string to access the switch with read-write permission, or use
public as the community string to access the switch with read-only permission.
Scenario 6: NMS will receive Trap messages from the switch (Note: NMS may have community string
verification for the Trap messages. In this scenario, the NMS uses a Trap verification community string of
dcstrap).
The configuration on the switch is listed below:
Switch(config)#snmp
-server host 2004:1:2:3::2 v1 dcstrap
Switch(config)#snmp-server enable traps
4.4.6 SNMP Troubleshooting
When users configure the SNMP, the SNMP server may fail to run properly due to physical connection failure
and wrong configuration, etc. Users can troubleshoot the problems by following the guide below:
Good condition of the physical connection.
Interface and datalink layer protocol is Up (use the “show interface” command), and the connection
between the switch and host can be verified by ping (use “ping” command).