ifOutNUcastPkts The number of broad-cast and multi-cast packets that request to transmit
ifOutOctets The number of octets transmitted out of the interface, including framing characters
<uint> ifIndex
<interval: 1-2147483647> Sample interval
absolute Test each sample directly
delta Test delta between samples
rising-threshold Configure the rising threshold
<rising_threshold: -2147483648-2147483647> rising threshold value
<rising_event_id: 0-65535> Event to fire on rising threshold crossing
falling-threshold Configure the falling threshold
<falling_threshold: -2147483648-2147483647> falling threshold value
<falling_event_id: 0-65535> Event to fire on falling threshold crossing
both Trigger alarm when the first value is larger than the rising threshold or less than the falling threshold (default)
falling Trigger alarm when the first value is less than the falling threshold
rising Trigger alarm when the first value is larger than the rising threshold
Default:
None
Usage Guide:
To configure the Alarm of RMON
Example:
To configure the Alarm (below table) of RMON
Switch# configure terminal
Switch (config)# rmon alarm 1 .1.3.6.1.2.1.2.2.1.10.15 50 absolute rising-threshold
1000 1 falling-threshold 520 1 falling
4.2.190 rmon event
Command:
rmon event <id: 1-65535> [ log ] [ trap <community> ] { [ description <description> ] }
rmon Remote Monitoring
event Configure an RMON event
<id: 1-65535> Event entry ID
description Specify a description of the event