Command Guide of MGSW-28240F
<Lckprio : 0-7> LCK injection priority value.
lck-highest Request the highest possible LCK priority.
Default:
0
Usage Guide:
To configure Client Flow of MEP
Example:
To configure Client Flow of MEP 1 as below table.
Switch# configure terminal
Switch (config)# mep 1 client flow 5 level 4 ais-prio ais-highest lck-prio 3
4.2.119 mep <Instance> dm
Command:
mep <Instance> dm <prio> [ multi | { uni mep-id <mepid> } ] [ single | dual ] [ rdtrp |
flow ] interval <interval> last-n <lastn>
mep Maintenance Entity Point
<Instance> The MEP instance number.
dm Delay Measurement
<Prio : 0-7> Priority in case of tagged OAM. In the EVC domain this is the COS-ID
dual Delay Measurement based on 1DM PDU transmission.
flow The two way delay is calculated as round trip symmetrical flow delay. The far end residence time is
subtracted.
interval Interval between PDU transmission in 10ms. Min value is 10.
<Interval : uint> Interval value
multi OAM PDU is transmitted with multicast MAC.
rdtrp The two way delay is calculated as round trip delay. The far end residence time is not subtracted.
single Delay Measurement based on DMM/DMR PDU.
-233
-