Parameters:
<hold_timeout>: timer timeout values
<group-id> : protection group id 1 - 64
ERPS Guard-timeout
Description:
configuring guard timeout for a protection group
guard timeout should be configured in the increments of 10 milliseconds
minimum guard timeout 10ms and maximum 2 seconds
<guard_timeout> : guard timeout
<group-id> : protection group id for configuring guard time.
Syntax:
Erps guard-timeout <guard_timeout> <group-id>
Parameters:
<guard_timeout>: timer timeout values
<group-id> : protection group id 1 - 64
ERPS WRT-timeout
Description:
configuring wait to restore timeout for a protection group
in minutes in the range of 1 to 12 minutes
<wtr_timeout> : configuring wtr timeout
<group-id> : protection group id for configuring wtr time.
Syntax:
Erps wtr-timeout <wtr_timeout> <group-id>
Parameters:
<wtr_timeout>: timer timeout values
<group-id> : protection group id 1 - 64