Planet IGS-10020HPT User Manual Page 346

  • Download
  • Add to my manuals
  • Print
  • Page
    / 658
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 345
Users Manual of IGS-10020PT / IGS-10020HPT
346
Shutdown Time
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action shuts down the port). Valid values are 0 to
604800 seconds (7 days). A value of zero will keep a port disabled (until next
device restart).
Port Configuration:
Object Description
Port
The switch port number of the port.
Enable
Controls whether loop protection is enabled on this switch port.
Action
Configures the action performed when a loop is detected on a port. Valid values
are Shutdown Port, Shutdown Port and Log or Log Only.
Tx Mode
Controls whether the port is actively generating loop protection PDU's, or
whether it is just passively looking for looped PDU's.
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.
4.17.2 Status
This page displays the loop protection port status the ports from the Industrial Managed Switch.
Figure 4-17-2: Loop Protection Status Page Screenshot
The page includes the following fields:
Object Description
Port
The switch port number of the logical port.
Action
The currently configured port action.
Transmit
The currently configured port transmit mode.
Page view 345
1 2 ... 341 342 343 344 345 346 347 348 349 350 351 ... 657 658

Comments to this Manuals

No comments