User’s Manual of FGSD-1022 User’s Manual FGSD-1022 8-Port 10/100Mbps + 2 Gigabit TP/SFP Layer 2 Managed Switch FGSD-1022P 8-Port 10/100Mbps
User’s Manual of FGSD-1022 Series 10 1.2 Product Description High Performance Wire-Speed Switching The PLANET FGSD-1022 Series Managed Switch offers
User’s Manual of FGSD-1022 Series 4.6.1 Aggregator setting This section provides Port Trunk-Aggregator Setting of each port from the Managed Switch, t
User’s Manual of FGSD-1022 Series Work ports: This column field allows the user to type in the total number of active port up to four. With LACP stati
User’s Manual of FGSD-1022 Series Figure 4-6-3: Static Trunking Group information The page includes the following fields: Object Description Group
User’s Manual of FGSD-1022 Series Figure 4-6-4: Aggregation Information of Switch 1 5. Click on the tab of Aggregator Information to check the trun
User’s Manual of FGSD-1022 Series Figure 4-6-5: Switch 2 configuration interface 10. Click on the tab of Aggregator Information to check the trunke
User’s Manual of FGSD-1022 Series 4.6.3 State Activity Having set up the LACP aggregator on the tab of Aggregator Setting, you can configure the state
User’s Manual of FGSD-1022 Series 4.7 Forwarding and Filtering The frames of Ethernet Packets contain a MAC address (SMAC address), which shows the MA
User’s Manual of FGSD-1022 Series 107 MAC Table Columns Object Description NO The MAC addresses index entry. MAC The MAC address of the entry. PORT T
User’s Manual of FGSD-1022 Series Figure 4-7-2: Static MAC Addresses interface The page includes the following fields: Object Description MAC Addre
User’s Manual of FGSD-1022 Series 4.7.3 MAC Filtering By filtering MAC address, the switch can easily filter the pre-configured MAC address and reduce
User’s Manual of FGSD-1022 Power over Ethernet of FGSD-1022P The PoE in-line power following the standard IEEE 802.3af / IEEE 802.3at makes the FGSD-
User’s Manual of FGSD-1022 Series 4.8 IGMP Snooping 4.8.1 Theory The Internet Group Management Protocol (IGMP) lets host and routers share informatio
User’s Manual of FGSD-1022 Series Figure 4-8-2: Multicast flooding Figure 4-8-3: IGMP Snooping multicast stream control 111
User’s Manual of FGSD-1022 Series 112 IGMP Versions 1 and 2 Multicast groups allow members to join or leave at any time. IGMP provides the method for
User’s Manual of FGSD-1022 Series The states a computer will go through to join or to leave a multicast group are shown below: Figure 4-8-4: IGMP St
User’s Manual of FGSD-1022 Series 4.8.2 IGMP Configuration The Managed Switch support IP multicast, you can enable IGMP protocol on web management’s s
User’s Manual of FGSD-1022 Series The page includes the following fields: Object Description IGMP Protocol: Enable or disable the IGMP protocol. IGM
User’s Manual of FGSD-1022 Series 4.8.3 Static Multicast Table Static Multicast Table is a feature for user to force steaming multicast stream to indi
User’s Manual of FGSD-1022 Series The page includes the following fields: Object Description IP Address: Allows user to input multicast address grou
User’s Manual of FGSD-1022 Series 118 4.9 QoS Configuration 4.9.1 Understand QoS Quality of Service (QoS) is an advanced traffic prioritization fea
User’s Manual of FGSD-1022 Series 4.9.2 QoS Configuration QoS settings allow customization of packet priority in order to facilitate delivery of data
User’s Manual of FGSD-1022 Series 12 1.4 Product Features Physical Port FGSD-1022 8-Port 10/100Base-TX RJ-45 interfaces 2 10/100/1000T TP c
User’s Manual of FGSD-1022 Series The table includes the following fields: Object Description First Come First Service The sequence of packets sent i
User’s Manual of FGSD-1022 Series 4.9.2.2 QoS PerPort Configuration Configure the priority level for each port. With the drop-down selection item of P
User’s Manual of FGSD-1022 Series 4.9.3 TOS/DSCP TOS/DSCP priority is obtained through a 6-bit Type-of-Service (TOS) or Differentiated Service Code Po
User’s Manual of FGSD-1022 Series 4.9.3.1 TOS/DSCP Configuration The TOS/DSCP page provides fields for defining output queue to specific DSCP fields.
User’s Manual of FGSD-1022 Series 4.9.3.2 TOS/DSCP Port Configuration Set up IP TOS / DSCP mapping to 802.1p priority when receiving IPv4 packets, the
User’s Manual of FGSD-1022 Series 4.10 Access Control List The Access Control List (ACL) is a concept in computer security used to enforce privilege s
User’s Manual of FGSD-1022 Series 126 The page includes the following fields: IPv4 ACL Object Description Default VauleGroup ID 1 ~ 220 (max. 2
User’s Manual of FGSD-1022 Series 127 number. TCP Set this field if Packet Type is IPv4, else ignore. Any / FTP(21) / HTTP(80) Any Port Set this field
User’s Manual of FGSD-1022 Series 128 Binding Let device that has specific IP address and MAC address can use network. We can set specific IP addre
User’s Manual of FGSD-1022 Series 4.11 MAC Limit MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table
User’s Manual of FGSD-1022 Series 13 Quality of Service 4 priority queues on all switch ports Traffic classification: IEEE 802.1p Class of
User’s Manual of FGSD-1022 Series 4.11.2 MAC Limit Port Status This table displays current MAC Limit status of each port. Figure 4-11-2: MAC Limit –
User’s Manual of FGSD-1022 Series 4.12 802.1X Configuration 802.1x is an IEEE authentication specification which prevents the client from accessing a
User’s Manual of FGSD-1022 Series Control Server version 3.0. RADIUS operates in a client/server model in which secure authentication information is e
User’s Manual of FGSD-1022 Series Figure 4-12-2: EAP message exchange Ports in Authorized and Unauthorized States The switch port state determine
User’s Manual of FGSD-1022 Series 4.12.2 System Configuration 802.1x makes use of the physical access characteristics of IEEE802 LAN infrastructures i
User’s Manual of FGSD-1022 Series 135 The page includes the following fields: Object Description IEEE 802.1x Protocol: Enable or disable 802.1x proto
User’s Manual of FGSD-1022 Series 4.12.3 802.1x Port Configuration In this page, you can select the specific port and configure the authorization stat
User’s Manual of FGSD-1022 Series 4.12.4 Misc Configuration In this page, you can change the default configuration for the 802.1x standard: Figure 4-
User’s Manual of FGSD-1022 Series 4.13 Power over Ethernet (FGSD-1022P / FGSD-1022HP) Providing up to 8 PoE, in-line power interface, the FGSD-1022P /
User’s Manual of FGSD-1022 Series 4.13.2 FGSD-1022P / FGSD-1022HP Power Management In a power over Ethernet system, operating power is applied from a
User’s Manual of FGSD-1022 Series 14 Auto detect powered device (PD) Circuit protection prevent power interference between ports Remote power
User’s Manual of FGSD-1022 Series 140 The page includes the following fields: Object Description PoE PSU Status PoE PSU Status shows status of power
User’s Manual of FGSD-1022 Series Consumption [W] It shows the PoE device current watt. Power Limit It can limit the port PoE supply watts. Per port
User’s Manual of FGSD-1022 Series 142 The page includes the following fields: Object Description System PoE Admin Mode Allows user enable or disable
User’s Manual of FGSD-1022 Series Device class Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to pro
User’s Manual of FGSD-1022 Series 4.13.3 PoE Schedule PoE Schedule allows user to scheduling PoE power supply. User has to define when system supplies
User’s Manual of FGSD-1022 Series Figure 4-13-4: PoE Configuration Interface 145
User’s Manual of FGSD-1022 Series 146 4.14 DHCP Relay & Option 82 The Relay Agent Information option (Option82) is inserted by the DHCP relay agen
User’s Manual of FGSD-1022 Series Figure 4-14-1: DHCP Relay & Option 82 The page includes the following fields: Object Description DHCP Option
User’s Manual of FGSD-1022 Series 4.15 LLDP Link Layer Discovery Protocol (LLDP) is used to discover basic information about neighboring devices on th
User’s Manual of FGSD-1022 Series 4.15.2 Per Port Configuration This page allows the user to inspect and configure the current LLDP port settings. The
User’s Manual of FGSD-1022 Series 15 1.5 Product Specification Product FGSD-1022 FGSD-1022P FGSD-1022HP Hardware Specification 10/100Mbps Copper P
User’s Manual of FGSD-1022 Series 4.16 User Configuration This web page provide user configuration for switch management access level, the web screen
User’s Manual of FGSD-1022 Series 151 The page includes the following fields: Object Description User Name: Assign Username for the Managed Switch. A
User’s Manual of FGSD-1022 Series 5. CONSOLE MANAGEMENT The PLANET FGSD-1022 series is equipped with a RS-232 DB9 connector as default. And both of t
User’s Manual of FGSD-1022 Series 153 1. For security reason, please change and memorize the new username and password after this first setup. Us
User’s Manual of FGSD-1022 Configure IP address 1. On “Switch(config)# ” prompt, enter the following command and press <Enter>. As show in Fi
User’s Manual of FGSD-1022 Series 155 5.3 Commands Level The following table lists the CLI commands and description. Modes Access Method Prompt Ex
User’s Manual of FGSD-1022 Series 156 6. COMMAND LINE INTERFACE 6.1 Operation Notice To enter the “configuration” mode, you need to be in the privil
User’s Manual of FGSD-1022 Series 157 6.1.2. Command Help You may enter ? at any command mode, and the CLI will return possible commands at that point
User’s Manual of FGSD-1022 Series 158 6.3 Switch Static Configuration 6.3.1 Port Configuration and show status port state Turn the port state on or o
User’s Manual of FGSD-1022 Series 159 port rate Description: Set port effective ingress or egress rate. Syntax: port rate <ingress | egress> <
User’s Manual of FGSD-1022 Series 16 Port Status Display each port’s speed duplex mode, link status, Flow control status. Auto negotiation status VLAN
User’s Manual of FGSD-1022 Series 160 Port 2 Information ---------------------------------------------------------------------- State: on Link: do
User’s Manual of FGSD-1022 Series 161 show port protection Description: Show protected port information. Switch(config)# show port protection ------
User’s Manual of FGSD-1022 Series 6.4 Trunk Configuration Trunk allows the switch to combine ports so that they function like a single high-speed link
User’s Manual of FGSD-1022 Series 163 no trunk Description: Delete an existing trunk group. Syntax: no trunk <trunk-id> Parameters: <trunk-id
User’s Manual of FGSD-1022 Series show lacp agg Description: Show LACP aggregator information. Syntax: show lacp agg <trunk-id> Parameters: <
User’s Manual of FGSD-1022 Series 165 6.5 VLAN Configuration 6.5.1 Virtual LANs A Virtual LAN (VLAN) is a logical network group that limits the broad
User’s Manual of FGSD-1022 Series 166 The FGSD-1022 series support both Port-based VLAN and Tag-based (802.1Q) VLAN modes. The default configuration i
User’s Manual of FGSD-1022 6.5.3 Advanced 802.1Q VLAN Configuration Ingress filters configuration When a packet was received on a port, you can govern
User’s Manual of FGSD-1022 Series 168 This VLAN entry has four members (from port1 to port4) and all members are untagged. no vlan Description: Delete
User’s Manual of FGSD-1022 Series 169 show vlan pvid Description: Show port default VLAN id. Syntax: show vlan pvid [LIST] Parameters: [LIST] specifi
User’s Manual of FGSD-1022 Series 17 PoE Power output - Per Port 48V DC, 350mA . Max. 15.4 Watts Per Port 56V DC, 600mA Max. 30 Watts Power Pin Assign
User’s Manual of FGSD-1022 Series 170 Switch(config)# show vlan filter Port | Rule 1 | Rule 2 Filter (nonmbr) (untag) -----------+------------+
User’s Manual of FGSD-1022 Series 171 Unicast/Multicast: Flood unicast/multicast filter Control Packets: Control packets filter IP multicast:
User’s Manual of FGSD-1022 Series 172 Parameters: The manager username and password is also used by the web UI. 6.7.2 IP Configuration User can conf
User’s Manual of FGSD-1022 Series dhcp Description: Set switch as dhcp client, it can get ip from dhcp server. If you set this command, the switch w
User’s Manual of FGSD-1022 Series 174 6.7.6 Restore Configure File copy tftp <running-config | flash> Description: Retrieve configuration from
User’s Manual of FGSD-1022 Series no mac-limit Description: Disable MAC limit. Mac-limit Description: Set port MAC limit value, 0 to turn off MAC lim
User’s Manual of FGSD-1022 Series 176 show mirror-port Description: Show port monitoring information
User’s Manual of FGSD-1022 Series 177 6.10 Quality of Service There are four transmission queues with different priorities in the Managed Switch: High
User’s Manual of FGSD-1022 Series 178 [<highest-weight>][<sechighweight>][<sec low -weight>] [<lowest-weight>] e.g. qos priori
User’s Manual of FGSD-1022 Series 179 6.11 MAC Address Configuration clear mac-address-table Description: Clear all dynamic MAC address table entries.
User’s Manual of FGSD-1022 Series 2. INSTALLATION This section describes the hardware features and installation of the Managed Switch on the desktop
User’s Manual of FGSD-1022 Series 180 smac-address-table static Description: Set static unicast or multicast MAC address in secondary MAC address tabl
User’s Manual of FGSD-1022 Series 6.12 STP/MSTP Commands [no] spanning-tree Description: Enable or disable spanning-tree. spanning-tree forward-delay
User’s Manual of FGSD-1022 Series The parameters must enforce the following relationships: 2*(hello-time + 1) <= maximum-age <= 2*(forward-dela
User’s Manual of FGSD-1022 Series 183 spanning-tree max-hops Description: Set spanning tree bridge maximum hops of CIST and all MSTIs. Syntax: spanni
User’s Manual of FGSD-1022 Series 184 Parameters: <0-240> specifies the port priority. The value must be in steps of 16. <port-list> speci
User’s Manual of FGSD-1022 Series 185 spanning-tree mst Description: Set spanning tree bridge priority of MSTI. Syntax: spanning-tree mst <0-15&g
User’s Manual of FGSD-1022 Series 186 no spanning-tree mst Description: Delete the specific MSTI. Syntax: no spanning-tree mst <0-15> Parameter
User’s Manual of FGSD-1022 Series 187 show spanning-tree mst <0-15> port <1-10> Parameters: <0-15> specifies the MSTI instance ID. &
User’s Manual of FGSD-1022 Series 188 6.13 SNMP Any Network Management running the simple Network Management Protocol (SNMP) can be management the swi
User’s Manual of FGSD-1022 Series 189 e.g. snmp system-contact [email protected] show snmp system Description: Show SNMP system information. 6.13.2 Comm
User’s Manual of FGSD-1022 Series Gigabit SFP Slots Port-9, Port-10: 1000Base-SX/LX mini-GBIC slot, SFP (Small Factor Pluggable) transceiver module
User’s Manual of FGSD-1022 Series 190 Parameters: <ip-addr> specifies the IP address. <community-str> specifies the community string. <
User’s Manual of FGSD-1022 Series 191 igmp querier Description: Enable/disable IGMP snooping querier. Syntax: [no] igmp querier igmp CrossVLAN
User’s Manual of FGSD-1022 Series 192 6.15 802.1x Protocol dot1x Description: Enable or disable 802.1x. Syntax: [no] dot1x radius-server host Des
User’s Manual of FGSD-1022 Series 193 dot1x timeout quiet-period Description: Set 802.1x quiet period. (default: 60 seconds) Syntax: dot1x timeout qu
User’s Manual of FGSD-1022 Series 194 Parameters: <1..10> specifies the maximum request retries. dot1x timeout re-authperiod Description: Set 8
User’s Manual of FGSD-1022 Series 195 6.16 Access Control List Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed
User’s Manual of FGSD-1022 Series 196 Port ID : Any Hit Octet Count : 165074 Hit Packet count : 472 acl (add|edit) <1-220> (permit|deny) <0-
User’s Manual of FGSD-1022 Series 197 <0-FF> specifies the protocol value. <0-FF> specifies the protocol mask. <0-FFFF> specifies th
User’s Manual of FGSD-1022 Series 198 6.17 Binding Let device that has specific IP address and MAC address can use network. We can set specific IP add
User’s Manual of FGSD-1022 Series 199 Parameters: <1-220> specifies the group id. A.B.C.D specifies the MAC address. <0-4094> specifies th
User’s Manual of FGSD-1022 Series 2 Trademarks Copyright PLANET Technology Corp. 2012. Contents subject to which revision without prior notice. PLAN
User’s Manual of FGSD-1022 Series Per 10/100/1000Base-T port /SFP interfaces LED Color Function LNK/ACT 1000 Green Lit: indicate that the port
User’s Manual of FGSD-1022 Series 6.18 Power over Ethernet Commands (PLANET FGSD-1022P / FGSD-1022HP) show poe Show System Power over Ethernet infor
User’s Manual of FGSD-1022 Series 201 show poe status Description: Show per PoE port information Command Level Global Configuration Syntax: show poe
User’s Manual of FGSD-1022 Series 6.18.2 Configure PoE Over Temperature Protection poe temperature-protection enable Description: Configure PoE over
User’s Manual of FGSD-1022 Series 203 6.18.3 Configure PoE -- System poe limit-mode Description: Configure System PoE power limit mode information C
User’s Manual of FGSD-1022 Series Parameters: <enable > Enable POE <disable > Disable POE. PoE admin-mode command has included in FGSD-1
User’s Manual of FGSD-1022 Series poe temperature Description: Configure System PoE Temperature Threshold information Command Level Global Configurat
User’s Manual of FGSD-1022 Series Parameters: <thershold> Thershold <0-100> Usage Threshold: 0~100% PoE usage command has included in FG
User’s Manual of FGSD-1022 Series 207 Switch(config)# Switch(config)# poe set profile1 1 on 3
User’s Manual of FGSD-1022 Series 208 6.18.4 Configure PoE -- Port poe enable Description: Enabling or disabling the port POE injects function. Co
User’s Manual of FGSD-1022 Series 209 poe priority Description: Set port priority for the power supply management. The command is configurable whi
User’s Manual of FGSD-1022 Series FGSD-1022HP LED indication Figure 2-6: FGSD-1022HP LED panel System LED Color Function PWR Green Lights to
User’s Manual of FGSD-1022 Series Example: Switch(config)# poe maximum-power 10 1 Switch(config)# show poe status 1 Port Admin Oper Power Mode Prio
User’s Manual of FGSD-1022 Series poe power-mode Description: Set poe power mode for the power supply management Command Level Global Configuration
User’s Manual of FGSD-1022 Series 212 6.19 SMTP Commands smtp Description: Enabling or disabling SMTP alarm function. Command Level: Global Con
User’s Manual of FGSD-1022 Series 213 Switch(config)# user add administrator New username: test New password for user: Retype new password: Switch(con
User’s Manual of FGSD-1022 Series 214 7. SWITCH OPERATION 7.1 Address Table The Switch is implemented with an address table. This address table compos
User’s Manual of FGSD-1022 Series 215 7.5 Auto-Negotiation The STP ports on the Switch have built-in "Auto-negotiation". This technology au
User’s Manual of FGSD-1022 Series 8. POWER OVER ETHERNET OVERVIEW What is PoE? Based on the global standard IEEE 802.3af, PoE is a technology for wir
User’s Manual of FGSD-1022 Series The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power
User’s Manual of FGSD-1022 Series 218 The PoE Provision Process While adding PoE support to networked devices is relatively painless, it should be rea
User’s Manual of FGSD-1022 Series 219 Start-up Once line detection and optional classification stages are completed, the PSE must switch from low volt
User’s Manual of FGSD-1022 Series 2.1.3 Switch Rear Panel The rear panel of the Managed Switch indicates an AC inlet power socket, which accepts input
User’s Manual of FGSD-1022 Series 220 9. TROUBLE SHOOTING This chapter contains information to help you solve problems. If the Ethernet Switch is not
User’s Manual of FGSD-1022 Series While IP Address be changed or forgotten admin password – To reset the IP address to the default IP Address “19
User’s Manual of FGSD-1022 Series Appendix A—RJ-45 Pin Assignment A.1 Switch's RJ-45 Pin Assignments 1000Mbps, 1000Base T Contact MDI MDI-X 1
User’s Manual of FGSD-1022 Series 223 The standard cable, RJ-45 pin assignment The standard RJ-45 receptacle/connector There are 8 wires on a sta
EC Declaration of Conformity For the following equipment: *Type of Product: 8-Port 10/100Mbps Fast Ethernet + 2 Gigabit TP/SFP combo Managed Eth
EC Declaration of Conformity For the following equipment: *Type of Product: 8-Port 10/100Mbps Fast Ethernet + 2 Gigabit TP/ SFP combo Managed Po
EC Declaration of Conformity For the following equipment: *Type of Product: 8-Port 10/100Mbps Fast Ethernet + 2 Gigabit TP/ SFP combo Managed 80
User’s Manual of FGSD-1022 Series 2.2 Install the Switch This section describes how to install the Managed Switch and make connections to it. Please r
User’s Manual of FGSD-1022 Series 2.2.2 Rack Mounting To install the Managed Switch in a 19-inch standard rack, please follows the instructions descri
User’s Manual of FGSD-1022 Series 2.2.3 Installing the SFP Transceiver The sections describe how to insert an SFP transceiver into an SFP slot. The SF
User’s Manual of FGSD-1022 Series 2. Check the fiber-optic cable type match the SFP transceiver model. To connect to 1000Base-SX SFP transceiver,
User’s Manual of FGSD-1022 Series Never pull out the module without pull the handle or the push bolts on the module. Direct pull out the module with
User’s Manual of FGSD-1022 Series 3. SWITCH MANAGEMENT This chapter explains the methods that you can use to configure management access to the Manag
User’s Manual of FGSD-1022 Series 29 3.2 Management Access Overview The Managed Switch gives you the flexibility to access and manage it using any or
User’s Manual of FGSD-1022 UL Warning This equipment is only to be connected to PoE networks without routing to outside plant. A) Elevated Operating
User’s Manual of FGSD-1022 Series 3.3 Web Management The Managed Switch offers management features that allow users to manage the Managed Switch from
User’s Manual of FGSD-1022 Series 3.4 SNMP-Based Network Management You can use an external SNMP-based application to configure and manage the Manag
User’s Manual of FGSD-1022 Series Direct Access Direct access to the administration console is achieved by directly connecting a terminal or a PC e
User’s Manual of FGSD-1022 Series 3.6 Protocols The Managed Switch supports the following protocols: Virtual terminal protocols, such as Telnet
User’s Manual of FGSD-1022 Series 4. Web-Based Management This section introduces the configuration and functions of the Web-Based management. 4.1 A
User’s Manual of FGSD-1022 Series 4.1.1 Requirements Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS9 or later, Linu
User’s Manual of FGSD-1022 Series 1. After entering the username and password, the main screen appears as Figure 4-1-2. Figure 4-1-2: Web main page
User’s Manual of FGSD-1022 Series 4.1.3 Main WEB PAGE The Managed Switch provides a Web-based browser interface for configuring and managing it. This
User’s Manual of FGSD-1022 Series The PoE Ports panel display is only for FGSD-1022P and FGSD-1022HP. Main Menu Using the onboard web agent, you c
User’s Manual of FGSD-1022 Series 4.2.1 System Information In System information, it has two parts of setting – Basic and Misc Config. We will describ
User’s Manual of FGSD-1022 Series 4 TABLE OF CONTENTS 1. INTRODUCTION ...
User’s Manual of FGSD-1022 Series 4.2.1.2 Misc Config Choose Misc Config from System Information of Managed Switch, the screen in Figure 4-2-2 appears
User’s Manual of FGSD-1022 Series 41 Mode individual ports. The threshold is the percentage of the port’s total bandwidth used by broadcast traffic. W
User’s Manual of FGSD-1022 Series 4.2.2 IP Configuration The Managed Switch is a network device which needs to be assigned an IP address for being ide
User’s Manual of FGSD-1022 Series 43 The page includes the following fields: Object Description DHCP Enable or disable the DHCP client function. Wh
User’s Manual of FGSD-1022 Series 4.2.3 SNMP Configuration 4.2.3.1 SNMP Overview The Simple Network Management Protocol (SNMP) is an application laye
User’s Manual of FGSD-1022 Series SNMP Operations SNMP itself is a simple request/response protocol. NMSs can send multiple requests without receiving
User’s Manual of FGSD-1022 Series System Contact The textual identification of the contact person for this managed node, together with information
User’s Manual of FGSD-1022 Series 4.2.3.4 Trap Managers A trap manager is a management station that receives the trap messages generated by the switch
User’s Manual of FGSD-1022 Series The page includes the following fields: Object Description Group Name: A string identifying the group name that t
User’s Manual of FGSD-1022 Series excluded: An optional flag to indicate that this view subtree should be excluded. View Subtree The OID defining t
User’s Manual of FGSD-1022 Series 5 4.2.3 SNMP Configuration...
User’s Manual of FGSD-1022 Series SNMP Access: Indicates the security model that this entry should belong to. Possible security models are: NoAu
User’s Manual of FGSD-1022 Series 51 None: None authentication protocol. MD5: An optional flag to indicate that this user using MD5 authentica
User’s Manual of FGSD-1022 Series 4.2.4 Firmware Upgrade It provides the functions allowing the user to update the switch firmware via the Trivial Fil
User’s Manual of FGSD-1022 Series 4.2.4.2 HTTP Firmware Upgrade The HTTP Firmware Upgrade page contains fields for downloading system image files from
User’s Manual of FGSD-1022 Series 4. Select on the firmware then click “Upload”, the Software Upload Progress would show the file upload status. Fi
User’s Manual of FGSD-1022 Series 4.2.5.2 TFTP Backup Configuration You can back up the current configuration from flash ROM to the TFTP server for th
User’s Manual of FGSD-1022 Series 4.2.6 Factory Default Reset switch to default configuration. Click Default to reset all configurations to the defau
User’s Manual of FGSD-1022 Series 4.2.8 Syslog Setting The Syslog Setting page allows you to configure the logging of messages that are sent to remo
User’s Manual of FGSD-1022 Series Figure 4-2-19 : SMTP interface The page includes the following fields: Object Description SMTP E-Mail Alarm Allo
User’s Manual of FGSD-1022 Series 4.2.10 SNTP It provides the functions allowing the user to update the switch firmware via the Trivial File Transfe
User’s Manual of FGSD-1022 Series 6 4.7.2 Static MAC Table...
User’s Manual of FGSD-1022 Series Figure 4-2-21 : System Log interface The page includes the following fields: Object Description System Log Mode
User’s Manual of FGSD-1022 Series 4.3 Port Configuration Use the Port Configuration Menu to display or configure the Managed Switch’s ports. This sect
User’s Manual of FGSD-1022 Series Speed It is available for selecting when the Negotiation column is set as Force. When the Negotiation column is set
User’s Manual of FGSD-1022 Series 4.3.2 Rate Control This page provides rate control on each port - it contains Ingress and Egress items and the unit
User’s Manual of FGSD-1022 Series 4.3.3 Port Status This page displays current port configurations and operating status – it is a ports’ configuration
User’s Manual of FGSD-1022 Series 65 The page includes the following fields: Object Description Port: The port number. Description Shows port descri
User’s Manual of FGSD-1022 Series 4.3.5 Port Sniffer The Port Sniffer (mirroring) is a method for monitor traffic in switched networks. Traffic throug
User’s Manual of FGSD-1022 Series Figure 4-3-6: Port Sniffer interface The page includes the following fields: Object Description Sniffer Type: Sel
User’s Manual of FGSD-1022 Series 4.3.6 Protect Port There are two protected port groups; ports in different groups can’t communicate. In the same gro
User’s Manual of FGSD-1022 Series 4.3.7 Remote Ping The Remote Ping allows user to check the device connection status via ping. Figure 4-3-8: Remote
User’s Manual of FGSD-1022 Series 7 6.3.1 Port Configuration and show status ...
User’s Manual of FGSD-1022 Series 4.4 VLAN configuration 4.4.1 VLAN Overview A Virtual Local Area Network (VLAN) is a network topology configured ac
User’s Manual of FGSD-1022 Series VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between statio
User’s Manual of FGSD-1022 Series Adding an IEEE802.1Q Tag 72 Dest. Addr. Src. Addr. Length/E. type Data Old CRC Dest. Addr. Src. Addr. E. typ
User’s Manual of FGSD-1022 Series 4.4.2 Static VLAN Configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain
User’s Manual of FGSD-1022 Series 4.4.3 Port-based VLAN Packets can go among only members of the same VLAN group. Note all unselected ports are treate
User’s Manual of FGSD-1022 Series By adding ports to the VLAN you have created one port-based VLAN group completely. Figure 4-4-3: Static VLAN inte
User’s Manual of FGSD-1022 Series 76 4.4.4 802.1Q VLAN Tagged-based VLAN is an IEEE 802.1Q specification standard. Therefore, it is possible to create
User’s Manual of FGSD-1022 Series 4.4.4.1 VLAN Group Configuration VLAN Group Configuration Figure 4-4-4: VLAN Group Configuration interface 1.
User’s Manual of FGSD-1022 Series Figure 4-4-5: VLAN Group Configuration interface 5. Select specific port as member port and the screen in Figure
User’s Manual of FGSD-1022 Series Figure 4-4-6: 802.1Q VLAN Setting Web Page screen The page includes the following fields: Object Description VLAN
User’s Manual of FGSD-1022 Series 8 6.18.1 Display System PoE status ...
User’s Manual of FGSD-1022 Series 4.4.4.2 VLAN Filter 802.1Q VLAN Port Configuration This page is used for configuring the Switch port VLAN. The VL
User’s Manual of FGSD-1022 Series The VLAN ID must as same as the VLAN ID that the port belong to VLAN group, or the untagged traffic will be dropped.
User’s Manual of FGSD-1022 Series The Managed Switch supports multiple VLAN tags and can therefore be used in MAN applications as a provider bridge, a
User’s Manual of FGSD-1022 Series 83 The page includes the following fields: Object Description Enable: Sets the Managed Switch to QinQ mode, and
User’s Manual of FGSD-1022 Series 4.4.5.2 Q-in-Q Tunnel Setting Business customers of service providers often have specific requirements for VLAN IDs
User’s Manual of FGSD-1022 Series 4.4.6 GVRP VLAN GVRP (GARP VLAN Registration Protocol or Generic VLAN Registration Protocol) is a protocol that faci
User’s Manual of FGSD-1022 Series 4.4.6.1 GVRP Setting To configure GVRP Enable global GVRP function: select GVRP enable “Enable”. Enable port GVRP
User’s Manual of FGSD-1022 Series 4.4.6.2 GVRP Table The GVRP Table can be used to display dynamic VLANs from being learned via GVRP. Figure 4-4-1
User’s Manual of FGSD-1022 Series 88 4.5 Spanning Tree Protocol 4.5.1 Theory The Spanning Tree protocol can be used to detect and disable network loo
User’s Manual of FGSD-1022 Series 89 Bridge Protocol Data Units For STP to arrive at a stable network topology, the following information is used:
User’s Manual of FGSD-1022 Series 9 1. Introduction The PLANET Layer 2 Managed Switch series - FGSD-1022, FGSD-1022P and FGSD-1022HP are multiple 10
User’s Manual of FGSD-1022 Series Each port on a switch using STP exists is in one of the following five states: Blocking – the port is blocked fro
User’s Manual of FGSD-1022 Series 4.5.2 Illustration of STP A simple illustration of three switches connected in a loop is depicted in the below diagr
User’s Manual of FGSD-1022 Series Figure 4-5-3: After Applying the STA Rules 4.5.3 STP Parameters STP Operation Levels The Switch allows for two le
User’s Manual of FGSD-1022 Series Priority A relative priority for each switch – lower numbers give a higher priority and a greater chance of a given
User’s Manual of FGSD-1022 Series Observe the following formulas when setting the above parameters: Max. Age _ 2 x (Forward Delay – 1 second) Max. Ag
User’s Manual of FGSD-1022 Series Max Age (6-40): The number of seconds a switch waits without receiving Spanning-tree Protocol configuration messages
User’s Manual of FGSD-1022 Series 96 The page includes the following fields: Object Description Priority The bridge identifier of the root bridge
User’s Manual of FGSD-1022 Series 4.5.5 Port Configuration This web page provides the port configuration interface for STP. You can assign higher or l
User’s Manual of FGSD-1022 Series Admin P2P: The rapid state transitions possible within STP are dependent upon whether the port concerned can only be
User’s Manual of FGSD-1022 Series 4.6 Trunking Port trunking is the combination of several ports or network cables to expand the connection speed beyo
Comments to this Manuals