Planet FGSD-1022 User Manual

Browse online or download User Manual for Routers Planet FGSD-1022. PLANET FGSD-1022 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 226
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - User’s Manual

User’s Manual of FGSD-1022 User’s Manual FGSD-1022 8-Port 10/100Mbps + 2 Gigabit TP/SFP Layer 2 Managed Switch FGSD-1022P 8-Port 10/100Mbps

Page 2 - WEEE Warning

User’s Manual of FGSD-1022 Series 10 1.2 Product Description High Performance Wire-Speed Switching The PLANET FGSD-1022 Series Managed Switch offers

Page 3 - Revision

User’s Manual of FGSD-1022 Series 4.6.1 Aggregator setting This section provides Port Trunk-Aggregator Setting of each port from the Managed Switch, t

Page 4 - TABLE OF CONTENTS

User’s Manual of FGSD-1022 Series Work ports: This column field allows the user to type in the total number of active port up to four. With LACP stati

Page 5

User’s Manual of FGSD-1022 Series Figure 4-6-3: Static Trunking Group information The page includes the following fields: Object Description Group

Page 6

User’s Manual of FGSD-1022 Series Figure 4-6-4: Aggregation Information of Switch 1 5. Click on the tab of Aggregator Information to check the trun

Page 7

User’s Manual of FGSD-1022 Series Figure 4-6-5: Switch 2 configuration interface 10. Click on the tab of Aggregator Information to check the trunke

Page 8

User’s Manual of FGSD-1022 Series 4.6.3 State Activity Having set up the LACP aggregator on the tab of Aggregator Setting, you can configure the state

Page 9 - 1. Introduction

User’s Manual of FGSD-1022 Series 4.7 Forwarding and Filtering The frames of Ethernet Packets contain a MAC address (SMAC address), which shows the MA

Page 10 - 1.2 Product Description

User’s Manual of FGSD-1022 Series 107 MAC Table Columns Object Description NO The MAC addresses index entry. MAC The MAC address of the entry. PORT T

Page 11 - 1.3 How to Use This Manual

User’s Manual of FGSD-1022 Series Figure 4-7-2: Static MAC Addresses interface The page includes the following fields: Object Description MAC Addre

Page 12 - 1.4 Product Features

User’s Manual of FGSD-1022 Series 4.7.3 MAC Filtering By filtering MAC address, the switch can easily filter the pre-configured MAC address and reduce

Page 13

User’s Manual of FGSD-1022 Power over Ethernet of FGSD-1022P The PoE in-line power following the standard IEEE 802.3af / IEEE 802.3at makes the FGSD-

Page 14

User’s Manual of FGSD-1022 Series 4.8 IGMP Snooping 4.8.1 Theory The Internet Group Management Protocol (IGMP) lets host and routers share informatio

Page 15 - 1.5 Product Specification

User’s Manual of FGSD-1022 Series Figure 4-8-2: Multicast flooding Figure 4-8-3: IGMP Snooping multicast stream control 111

Page 16

User’s Manual of FGSD-1022 Series 112 IGMP Versions 1 and 2 Multicast groups allow members to join or leave at any time. IGMP provides the method for

Page 17

User’s Manual of FGSD-1022 Series The states a computer will go through to join or to leave a multicast group are shown below: Figure 4-8-4: IGMP St

Page 18 - 2. INSTALLATION

User’s Manual of FGSD-1022 Series 4.8.2 IGMP Configuration The Managed Switch support IP multicast, you can enable IGMP protocol on web management’s s

Page 19 - 2.1.2 LED Indications

User’s Manual of FGSD-1022 Series The page includes the following fields: Object Description IGMP Protocol: Enable or disable the IGMP protocol. IGM

Page 20

User’s Manual of FGSD-1022 Series 4.8.3 Static Multicast Table Static Multicast Table is a feature for user to force steaming multicast stream to indi

Page 21

User’s Manual of FGSD-1022 Series The page includes the following fields: Object Description IP Address: Allows user to input multicast address grou

Page 22 - 2.1.3 Switch Rear Panel

User’s Manual of FGSD-1022 Series 118 4.9 QoS Configuration 4.9.1 Understand QoS Quality of Service (QoS) is an advanced traffic prioritization fea

Page 23 - 2.2 Install the Switch

User’s Manual of FGSD-1022 Series 4.9.2 QoS Configuration QoS settings allow customization of packet priority in order to facilitate delivery of data

Page 24 - 2.2.2 Rack Mounting

User’s Manual of FGSD-1022 Series 12 1.4 Product Features  Physical Port FGSD-1022  8-Port 10/100Base-TX RJ-45 interfaces  2 10/100/1000T TP c

Page 25

User’s Manual of FGSD-1022 Series The table includes the following fields: Object Description First Come First Service The sequence of packets sent i

Page 26

User’s Manual of FGSD-1022 Series 4.9.2.2 QoS PerPort Configuration Configure the priority level for each port. With the drop-down selection item of P

Page 27 - Switch

User’s Manual of FGSD-1022 Series 4.9.3 TOS/DSCP TOS/DSCP priority is obtained through a 6-bit Type-of-Service (TOS) or Differentiated Service Code Po

Page 28 - 3. SWITCH MANAGEMENT

User’s Manual of FGSD-1022 Series 4.9.3.1 TOS/DSCP Configuration The TOS/DSCP page provides fields for defining output queue to specific DSCP fields.

Page 29

User’s Manual of FGSD-1022 Series 4.9.3.2 TOS/DSCP Port Configuration Set up IP TOS / DSCP mapping to 802.1p priority when receiving IPv4 packets, the

Page 30 - 3.3 Web Management

User’s Manual of FGSD-1022 Series 4.10 Access Control List The Access Control List (ACL) is a concept in computer security used to enforce privilege s

Page 31 - 3.5 Administration Console

User’s Manual of FGSD-1022 Series 126 The page includes the following fields:  IPv4 ACL Object Description Default VauleGroup ID 1 ~ 220 (max. 2

Page 32 - Direct Access

User’s Manual of FGSD-1022 Series 127 number. TCP Set this field if Packet Type is IPv4, else ignore. Any / FTP(21) / HTTP(80) Any Port Set this field

Page 33 - 3.6 Protocols

User’s Manual of FGSD-1022 Series 128  Binding Let device that has specific IP address and MAC address can use network. We can set specific IP addre

Page 34 - 4. Web-Based Management

User’s Manual of FGSD-1022 Series 4.11 MAC Limit MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table

Page 35 - 4.1.2 Logging on the switch

User’s Manual of FGSD-1022 Series 13  Quality of Service  4 priority queues on all switch ports  Traffic classification:  IEEE 802.1p Class of

Page 36

User’s Manual of FGSD-1022 Series 4.11.2 MAC Limit Port Status This table displays current MAC Limit status of each port. Figure 4-11-2: MAC Limit –

Page 37 - 4.1.3 Main WEB PAGE

User’s Manual of FGSD-1022 Series 4.12 802.1X Configuration 802.1x is an IEEE authentication specification which prevents the client from accessing a

Page 38 - 4.2 System

User’s Manual of FGSD-1022 Series Control Server version 3.0. RADIUS operates in a client/server model in which secure authentication information is e

Page 39 - 4.2.1 System Information

User’s Manual of FGSD-1022 Series Figure 4-12-2: EAP message exchange  Ports in Authorized and Unauthorized States The switch port state determine

Page 40 - 4.2.1.2 Misc Config

User’s Manual of FGSD-1022 Series 4.12.2 System Configuration 802.1x makes use of the physical access characteristics of IEEE802 LAN infrastructures i

Page 41

User’s Manual of FGSD-1022 Series 135 The page includes the following fields: Object Description IEEE 802.1x Protocol: Enable or disable 802.1x proto

Page 42 - 4.2.2 IP Configuration

User’s Manual of FGSD-1022 Series 4.12.3 802.1x Port Configuration In this page, you can select the specific port and configure the authorization stat

Page 43

User’s Manual of FGSD-1022 Series 4.12.4 Misc Configuration In this page, you can change the default configuration for the 802.1x standard: Figure 4-

Page 44 - 4.2.3 SNMP Configuration

User’s Manual of FGSD-1022 Series 4.13 Power over Ethernet (FGSD-1022P / FGSD-1022HP) Providing up to 8 PoE, in-line power interface, the FGSD-1022P /

Page 45 - 4.2.3.2 System Options

User’s Manual of FGSD-1022 Series 4.13.2 FGSD-1022P / FGSD-1022HP Power Management In a power over Ethernet system, operating power is applied from a

Page 46 - 4.2.3.3 Community Strings

User’s Manual of FGSD-1022 Series 14  Auto detect powered device (PD)  Circuit protection prevent power interference between ports  Remote power

Page 47 - 4.2.3.5 SNMPv3 Groups

User’s Manual of FGSD-1022 Series 140 The page includes the following fields: Object Description PoE PSU Status PoE PSU Status shows status of power

Page 48 - 4.2.3.6 SNMPv3 View

User’s Manual of FGSD-1022 Series Consumption [W] It shows the PoE device current watt. Power Limit It can limit the port PoE supply watts. Per port

Page 49 - 4.2.3.7 SNMPv3 Access

User’s Manual of FGSD-1022 Series 142 The page includes the following fields: Object Description System PoE Admin Mode Allows user enable or disable

Page 50 - 4.2.3.8 SNMP V3 usm-user

User’s Manual of FGSD-1022 Series Device class Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to pro

Page 51

User’s Manual of FGSD-1022 Series 4.13.3 PoE Schedule PoE Schedule allows user to scheduling PoE power supply. User has to define when system supplies

Page 52 - 4.2.4 Firmware Upgrade

User’s Manual of FGSD-1022 Series Figure 4-13-4: PoE Configuration Interface 145

Page 53

User’s Manual of FGSD-1022 Series 146 4.14 DHCP Relay & Option 82 The Relay Agent Information option (Option82) is inserted by the DHCP relay agen

Page 54 - 4.2.5 Configuration Backup

User’s Manual of FGSD-1022 Series Figure 4-14-1: DHCP Relay & Option 82 The page includes the following fields: Object Description DHCP Option

Page 55

User’s Manual of FGSD-1022 Series 4.15 LLDP Link Layer Discovery Protocol (LLDP) is used to discover basic information about neighboring devices on th

Page 56 - 4.2.7 System Reboot

User’s Manual of FGSD-1022 Series 4.15.2 Per Port Configuration This page allows the user to inspect and configure the current LLDP port settings. The

Page 57 - 4.2.9 SMTP Setting

User’s Manual of FGSD-1022 Series 15 1.5 Product Specification Product FGSD-1022 FGSD-1022P FGSD-1022HP Hardware Specification 10/100Mbps Copper P

Page 58

User’s Manual of FGSD-1022 Series 4.16 User Configuration This web page provide user configuration for switch management access level, the web screen

Page 59 - 4.2.11 System Log

User’s Manual of FGSD-1022 Series 151 The page includes the following fields: Object Description User Name: Assign Username for the Managed Switch. A

Page 60

User’s Manual of FGSD-1022 Series 5. CONSOLE MANAGEMENT The PLANET FGSD-1022 series is equipped with a RS-232 DB9 connector as default. And both of t

Page 61 - 4.3 Port Configuration

User’s Manual of FGSD-1022 Series 153 1. For security reason, please change and memorize the new username and password after this first setup. Us

Page 62

User’s Manual of FGSD-1022  Configure IP address 1. On “Switch(config)# ” prompt, enter the following command and press <Enter>. As show in Fi

Page 63 - 4.3.2 Rate Control

User’s Manual of FGSD-1022 Series 155 5.3 Commands Level The following table lists the CLI commands and description. Modes Access Method Prompt Ex

Page 64 - 4.3.4 Port Statistics

User’s Manual of FGSD-1022 Series 156 6. COMMAND LINE INTERFACE 6.1 Operation Notice To enter the “configuration” mode, you need to be in the privil

Page 65

User’s Manual of FGSD-1022 Series 157 6.1.2. Command Help You may enter ? at any command mode, and the CLI will return possible commands at that point

Page 66 - 4.3.5 Port Sniffer

User’s Manual of FGSD-1022 Series 158 6.3 Switch Static Configuration 6.3.1 Port Configuration and show status port state Turn the port state on or o

Page 67

User’s Manual of FGSD-1022 Series 159 port rate Description: Set port effective ingress or egress rate. Syntax: port rate <ingress | egress> <

Page 68 - 4.3.6 Protect Port

User’s Manual of FGSD-1022 Series 16 Port Status Display each port’s speed duplex mode, link status, Flow control status. Auto negotiation status VLAN

Page 69 - 4.3.7 Remote Ping

User’s Manual of FGSD-1022 Series 160 Port 2 Information ---------------------------------------------------------------------- State: on Link: do

Page 70 - 4.4 VLAN configuration

User’s Manual of FGSD-1022 Series 161 show port protection Description: Show protected port information. Switch(config)# show port protection ------

Page 71 -  802.1Q VLAN Tags

User’s Manual of FGSD-1022 Series 6.4 Trunk Configuration Trunk allows the switch to combine ports so that they function like a single high-speed link

Page 72 -  Default VLANs

User’s Manual of FGSD-1022 Series 163 no trunk Description: Delete an existing trunk group. Syntax: no trunk <trunk-id> Parameters: <trunk-id

Page 73

User’s Manual of FGSD-1022 Series show lacp agg Description: Show LACP aggregator information. Syntax: show lacp agg <trunk-id> Parameters: <

Page 74 - 4.4.3 Port-based VLAN

User’s Manual of FGSD-1022 Series 165 6.5 VLAN Configuration 6.5.1 Virtual LANs A Virtual LAN (VLAN) is a logical network group that limits the broad

Page 75

User’s Manual of FGSD-1022 Series 166 The FGSD-1022 series support both Port-based VLAN and Tag-based (802.1Q) VLAN modes. The default configuration i

Page 76 - 4.4.4 802.1Q VLAN

User’s Manual of FGSD-1022 6.5.3 Advanced 802.1Q VLAN Configuration Ingress filters configuration When a packet was received on a port, you can govern

Page 77 - VLAN Group Configuration

User’s Manual of FGSD-1022 Series 168 This VLAN entry has four members (from port1 to port4) and all members are untagged. no vlan Description: Delete

Page 78

User’s Manual of FGSD-1022 Series 169 show vlan pvid Description: Show port default VLAN id. Syntax: show vlan pvid [LIST] Parameters: [LIST] specifi

Page 79

User’s Manual of FGSD-1022 Series 17 PoE Power output - Per Port 48V DC, 350mA . Max. 15.4 Watts Per Port 56V DC, 600mA Max. 30 Watts Power Pin Assign

Page 80 - 4.4.4.2 VLAN Filter

User’s Manual of FGSD-1022 Series 170 Switch(config)# show vlan filter Port | Rule 1 | Rule 2 Filter (nonmbr) (untag) -----------+------------+

Page 81 - 4.4.5 Q-in-Q VLAN

User’s Manual of FGSD-1022 Series 171  Unicast/Multicast: Flood unicast/multicast filter  Control Packets: Control packets filter  IP multicast:

Page 82 - 4.4.5.1 Q-in-Q Port Setting

User’s Manual of FGSD-1022 Series 172 Parameters: The manager username and password is also used by the web UI. 6.7.2 IP Configuration User can conf

Page 83

User’s Manual of FGSD-1022 Series dhcp Description: Set switch as dhcp client, it can get ip from dhcp server. If you set this command, the switch w

Page 84 -  To configure QinQ Port

User’s Manual of FGSD-1022 Series 174 6.7.6 Restore Configure File copy tftp <running-config | flash> Description: Retrieve configuration from

Page 85 - 4.4.6 GVRP VLAN

User’s Manual of FGSD-1022 Series no mac-limit Description: Disable MAC limit. Mac-limit Description: Set port MAC limit value, 0 to turn off MAC lim

Page 86 - 4.4.6.1 GVRP Setting

User’s Manual of FGSD-1022 Series 176 show mirror-port Description: Show port monitoring information

Page 87 - 4.4.6.2 GVRP Table

User’s Manual of FGSD-1022 Series 177 6.10 Quality of Service There are four transmission queues with different priorities in the Managed Switch: High

Page 88 - 4.5 Spanning Tree Protocol

User’s Manual of FGSD-1022 Series 178 [<highest-weight>][<sechighweight>][<sec low -weight>] [<lowest-weight>] e.g. qos priori

Page 89

User’s Manual of FGSD-1022 Series 179 6.11 MAC Address Configuration clear mac-address-table Description: Clear all dynamic MAC address table entries.

Page 90

User’s Manual of FGSD-1022 Series 2. INSTALLATION This section describes the hardware features and installation of the Managed Switch on the desktop

Page 91 - 4.5.2 Illustration of STP

User’s Manual of FGSD-1022 Series 180 smac-address-table static Description: Set static unicast or multicast MAC address in secondary MAC address tabl

Page 92 - 4.5.3 STP Parameters

User’s Manual of FGSD-1022 Series 6.12 STP/MSTP Commands [no] spanning-tree Description: Enable or disable spanning-tree. spanning-tree forward-delay

Page 93

User’s Manual of FGSD-1022 Series The parameters must enforce the following relationships: 2*(hello-time + 1) <= maximum-age <= 2*(forward-dela

Page 94

User’s Manual of FGSD-1022 Series 183 spanning-tree max-hops Description: Set spanning tree bridge maximum hops of CIST and all MSTIs. Syntax: spanni

Page 95 -  Root Bridge Information

User’s Manual of FGSD-1022 Series 184 Parameters: <0-240> specifies the port priority. The value must be in steps of 16. <port-list> speci

Page 96

User’s Manual of FGSD-1022 Series 185 spanning-tree mst Description: Set spanning tree bridge priority of MSTI. Syntax: spanning-tree mst <0-15&g

Page 97 - 4.5.5 Port Configuration

User’s Manual of FGSD-1022 Series 186 no spanning-tree mst Description: Delete the specific MSTI. Syntax: no spanning-tree mst <0-15> Parameter

Page 98

User’s Manual of FGSD-1022 Series 187 show spanning-tree mst <0-15> port <1-10> Parameters: <0-15> specifies the MSTI instance ID. &

Page 99 - 4.6 Trunking

User’s Manual of FGSD-1022 Series 188 6.13 SNMP Any Network Management running the simple Network Management Protocol (SNMP) can be management the swi

Page 100 - 4.6.1 Aggregator setting

User’s Manual of FGSD-1022 Series 189 e.g. snmp system-contact [email protected] show snmp system Description: Show SNMP system information. 6.13.2 Comm

Page 101 - 4.6.2 Aggregator Information

User’s Manual of FGSD-1022 Series Gigabit SFP Slots Port-9, Port-10: 1000Base-SX/LX mini-GBIC slot, SFP (Small Factor Pluggable) transceiver module

Page 102 -  Switch 1 configuration

User’s Manual of FGSD-1022 Series 190 Parameters: <ip-addr> specifies the IP address. <community-str> specifies the community string. <

Page 103 -  Switch 2 configuration

User’s Manual of FGSD-1022 Series 191 igmp querier Description: Enable/disable IGMP snooping querier. Syntax: [no] igmp querier igmp CrossVLAN

Page 104

User’s Manual of FGSD-1022 Series 192 6.15 802.1x Protocol dot1x Description: Enable or disable 802.1x. Syntax: [no] dot1x radius-server host Des

Page 105 - 4.6.3 State Activity

User’s Manual of FGSD-1022 Series 193 dot1x timeout quiet-period Description: Set 802.1x quiet period. (default: 60 seconds) Syntax: dot1x timeout qu

Page 106 - 4.7 Forwarding and Filtering

User’s Manual of FGSD-1022 Series 194 Parameters: <1..10> specifies the maximum request retries. dot1x timeout re-authperiod Description: Set 8

Page 107 - 4.7.2 Static MAC Table

User’s Manual of FGSD-1022 Series 195 6.16 Access Control List Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed

Page 108

User’s Manual of FGSD-1022 Series 196 Port ID : Any Hit Octet Count : 165074 Hit Packet count : 472 acl (add|edit) <1-220> (permit|deny) <0-

Page 109 - 4.7.3 MAC Filtering

User’s Manual of FGSD-1022 Series 197 <0-FF> specifies the protocol value. <0-FF> specifies the protocol mask. <0-FFFF> specifies th

Page 110 - 4.8 IGMP Snooping

User’s Manual of FGSD-1022 Series 198 6.17 Binding Let device that has specific IP address and MAC address can use network. We can set specific IP add

Page 111

User’s Manual of FGSD-1022 Series 199 Parameters: <1-220> specifies the group id. A.B.C.D specifies the MAC address. <0-4094> specifies th

Page 112

User’s Manual of FGSD-1022 Series 2 Trademarks Copyright  PLANET Technology Corp. 2012. Contents subject to which revision without prior notice. PLAN

Page 113

User’s Manual of FGSD-1022 Series  Per 10/100/1000Base-T port /SFP interfaces LED Color Function LNK/ACT 1000 Green Lit: indicate that the port

Page 114 - 4.8.2 IGMP Configuration

User’s Manual of FGSD-1022 Series 6.18 Power over Ethernet Commands (PLANET FGSD-1022P / FGSD-1022HP) show poe Show System Power over Ethernet infor

Page 115

User’s Manual of FGSD-1022 Series 201 show poe status Description: Show per PoE port information Command Level Global Configuration Syntax: show poe

Page 116 - 4.8.3 Static Multicast Table

User’s Manual of FGSD-1022 Series 6.18.2 Configure PoE Over Temperature Protection poe temperature-protection enable Description: Configure PoE over

Page 117

User’s Manual of FGSD-1022 Series 203 6.18.3 Configure PoE -- System poe limit-mode Description: Configure System PoE power limit mode information C

Page 118 - 4.9 QoS Configuration

User’s Manual of FGSD-1022 Series Parameters: <enable > Enable POE <disable > Disable POE. PoE admin-mode command has included in FGSD-1

Page 119 - 4.9.2 QoS Configuration

User’s Manual of FGSD-1022 Series poe temperature Description: Configure System PoE Temperature Threshold information Command Level Global Configurat

Page 120

User’s Manual of FGSD-1022 Series Parameters: <thershold> Thershold <0-100> Usage Threshold: 0~100% PoE usage command has included in FG

Page 121

User’s Manual of FGSD-1022 Series 207 Switch(config)# Switch(config)# poe set profile1 1 on 3

Page 122 - 4.9.3 TOS/DSCP

User’s Manual of FGSD-1022 Series 208 6.18.4 Configure PoE -- Port poe enable Description: Enabling or disabling the port POE injects function. Co

Page 123

User’s Manual of FGSD-1022 Series 209 poe priority Description: Set port priority for the power supply management. The command is configurable whi

Page 124

User’s Manual of FGSD-1022 Series FGSD-1022HP LED indication Figure 2-6: FGSD-1022HP LED panel  System LED Color Function PWR Green Lights to

Page 125 - 4.10 Access Control List

User’s Manual of FGSD-1022 Series Example: Switch(config)# poe maximum-power 10 1 Switch(config)# show poe status 1 Port Admin Oper Power Mode Prio

Page 126

User’s Manual of FGSD-1022 Series poe power-mode Description: Set poe power mode for the power supply management Command Level Global Configuration

Page 127

User’s Manual of FGSD-1022 Series 212 6.19 SMTP Commands smtp Description: Enabling or disabling SMTP alarm function. Command Level: Global Con

Page 128

User’s Manual of FGSD-1022 Series 213 Switch(config)# user add administrator New username: test New password for user: Retype new password: Switch(con

Page 129 - 4.11 MAC Limit

User’s Manual of FGSD-1022 Series 214 7. SWITCH OPERATION 7.1 Address Table The Switch is implemented with an address table. This address table compos

Page 130 - 4.11.2 MAC Limit Port Status

User’s Manual of FGSD-1022 Series 215 7.5 Auto-Negotiation The STP ports on the Switch have built-in "Auto-negotiation". This technology au

Page 131 - 4.12 802.1X Configuration

User’s Manual of FGSD-1022 Series 8. POWER OVER ETHERNET OVERVIEW What is PoE? Based on the global standard IEEE 802.3af, PoE is a technology for wir

Page 132

User’s Manual of FGSD-1022 Series The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power

Page 133

User’s Manual of FGSD-1022 Series 218 The PoE Provision Process While adding PoE support to networked devices is relatively painless, it should be rea

Page 134 - 4.12.2 System Configuration

User’s Manual of FGSD-1022 Series 219 Start-up Once line detection and optional classification stages are completed, the PSE must switch from low volt

Page 135

User’s Manual of FGSD-1022 Series 2.1.3 Switch Rear Panel The rear panel of the Managed Switch indicates an AC inlet power socket, which accepts input

Page 136

User’s Manual of FGSD-1022 Series 220 9. TROUBLE SHOOTING This chapter contains information to help you solve problems. If the Ethernet Switch is not

Page 137 - 4.12.4 Misc Configuration

User’s Manual of FGSD-1022 Series  While IP Address be changed or forgotten admin password – To reset the IP address to the default IP Address “19

Page 138

User’s Manual of FGSD-1022 Series Appendix A—RJ-45 Pin Assignment A.1 Switch's RJ-45 Pin Assignments 1000Mbps, 1000Base T Contact MDI MDI-X 1

Page 139

User’s Manual of FGSD-1022 Series 223 The standard cable, RJ-45 pin assignment The standard RJ-45 receptacle/connector There are 8 wires on a sta

Page 140

EC Declaration of Conformity For the following equipment: *Type of Product: 8-Port 10/100Mbps Fast Ethernet + 2 Gigabit TP/SFP combo Managed Eth

Page 141

EC Declaration of Conformity For the following equipment: *Type of Product: 8-Port 10/100Mbps Fast Ethernet + 2 Gigabit TP/ SFP combo Managed Po

Page 142

EC Declaration of Conformity For the following equipment: *Type of Product: 8-Port 10/100Mbps Fast Ethernet + 2 Gigabit TP/ SFP combo Managed 80

Page 143

User’s Manual of FGSD-1022 Series 2.2 Install the Switch This section describes how to install the Managed Switch and make connections to it. Please r

Page 144 - 4.13.3 PoE Schedule

User’s Manual of FGSD-1022 Series 2.2.2 Rack Mounting To install the Managed Switch in a 19-inch standard rack, please follows the instructions descri

Page 145

User’s Manual of FGSD-1022 Series 2.2.3 Installing the SFP Transceiver The sections describe how to insert an SFP transceiver into an SFP slot. The SF

Page 146

User’s Manual of FGSD-1022 Series 2. Check the fiber-optic cable type match the SFP transceiver model.  To connect to 1000Base-SX SFP transceiver,

Page 147

User’s Manual of FGSD-1022 Series Never pull out the module without pull the handle or the push bolts on the module. Direct pull out the module with

Page 148 - 4.15 LLDP

User’s Manual of FGSD-1022 Series 3. SWITCH MANAGEMENT This chapter explains the methods that you can use to configure management access to the Manag

Page 149 - 4.15.2 Per Port Configuration

User’s Manual of FGSD-1022 Series 29 3.2 Management Access Overview The Managed Switch gives you the flexibility to access and manage it using any or

Page 150 - 4.16 User Configuration

User’s Manual of FGSD-1022 UL Warning This equipment is only to be connected to PoE networks without routing to outside plant. A) Elevated Operating

Page 151

User’s Manual of FGSD-1022 Series 3.3 Web Management The Managed Switch offers management features that allow users to manage the Managed Switch from

Page 152 - 5. CONSOLE MANAGEMENT

User’s Manual of FGSD-1022 Series 3.4 SNMP-Based Network Management You can use an external SNMP-based application to configure and manage the Manag

Page 153 - 5.2 Configure IP address

User’s Manual of FGSD-1022 Series Direct Access Direct access to the administration console is achieved by directly connecting a terminal or a PC e

Page 154 - User’s Manual of FGSD-1022

User’s Manual of FGSD-1022 Series 3.6 Protocols The Managed Switch supports the following protocols:  Virtual terminal protocols, such as Telnet 

Page 155 - 5.3 Commands Level

User’s Manual of FGSD-1022 Series 4. Web-Based Management This section introduces the configuration and functions of the Web-Based management. 4.1 A

Page 156 - 6. COMMAND LINE INTERFACE

User’s Manual of FGSD-1022 Series 4.1.1 Requirements  Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS9 or later, Linu

Page 157 - 6.2 System Commands

User’s Manual of FGSD-1022 Series 1. After entering the username and password, the main screen appears as Figure 4-1-2. Figure 4-1-2: Web main page

Page 158

User’s Manual of FGSD-1022 Series 4.1.3 Main WEB PAGE The Managed Switch provides a Web-based browser interface for configuring and managing it. This

Page 159

User’s Manual of FGSD-1022 Series The PoE Ports panel display is only for FGSD-1022P and FGSD-1022HP. Main Menu Using the onboard web agent, you c

Page 160

User’s Manual of FGSD-1022 Series 4.2.1 System Information In System information, it has two parts of setting – Basic and Misc Config. We will describ

Page 161

User’s Manual of FGSD-1022 Series 4 TABLE OF CONTENTS 1. INTRODUCTION ...

Page 162 - 6.4 Trunk Configuration

User’s Manual of FGSD-1022 Series 4.2.1.2 Misc Config Choose Misc Config from System Information of Managed Switch, the screen in Figure 4-2-2 appears

Page 163 - 6.4.2 LACP Command

User’s Manual of FGSD-1022 Series 41 Mode individual ports. The threshold is the percentage of the port’s total bandwidth used by broadcast traffic. W

Page 164 - VLAN group

User’s Manual of FGSD-1022 Series 4.2.2 IP Configuration The Managed Switch is a network device which needs to be assigned an IP address for being ide

Page 165 - 6.5 VLAN Configuration

User’s Manual of FGSD-1022 Series 43 The page includes the following fields: Object Description DHCP Enable or disable the DHCP client function. Wh

Page 166 - 6.5.2 VLAN Mode: Port-based

User’s Manual of FGSD-1022 Series 4.2.3 SNMP Configuration 4.2.3.1 SNMP Overview The Simple Network Management Protocol (SNMP) is an application laye

Page 167

User’s Manual of FGSD-1022 Series SNMP Operations SNMP itself is a simple request/response protocol. NMSs can send multiple requests without receiving

Page 168

User’s Manual of FGSD-1022 Series  System Contact The textual identification of the contact person for this managed node, together with information

Page 169

User’s Manual of FGSD-1022 Series 4.2.3.4 Trap Managers A trap manager is a management station that receives the trap messages generated by the switch

Page 170 - 6.6 Misc Configuration

User’s Manual of FGSD-1022 Series The page includes the following fields: Object Description Group Name: A string identifying the group name that t

Page 171

User’s Manual of FGSD-1022 Series  excluded: An optional flag to indicate that this view subtree should be excluded. View Subtree The OID defining t

Page 172 - 6.7.2 IP Configuration

User’s Manual of FGSD-1022 Series 5 4.2.3 SNMP Configuration...

Page 173 - 6.7.5 TFTP Update Firmware

User’s Manual of FGSD-1022 Series SNMP Access: Indicates the security model that this entry should belong to. Possible security models are:  NoAu

Page 174 - 6.8 MAC limit

User’s Manual of FGSD-1022 Series 51  None: None authentication protocol.  MD5: An optional flag to indicate that this user using MD5 authentica

Page 175

User’s Manual of FGSD-1022 Series 4.2.4 Firmware Upgrade It provides the functions allowing the user to update the switch firmware via the Trivial Fil

Page 176 - Description:

User’s Manual of FGSD-1022 Series 4.2.4.2 HTTP Firmware Upgrade The HTTP Firmware Upgrade page contains fields for downloading system image files from

Page 177 - 6.10 Quality of Service

User’s Manual of FGSD-1022 Series 4. Select on the firmware then click “Upload”, the Software Upload Progress would show the file upload status. Fi

Page 178 - 6.10.2 Per Port Priority

User’s Manual of FGSD-1022 Series 4.2.5.2 TFTP Backup Configuration You can back up the current configuration from flash ROM to the TFTP server for th

Page 179

User’s Manual of FGSD-1022 Series 4.2.6 Factory Default Reset switch to default configuration. Click Default to reset all configurations to the defau

Page 180

User’s Manual of FGSD-1022 Series 4.2.8 Syslog Setting The Syslog Setting page allows you to configure the logging of messages that are sent to remo

Page 181 - 6.12 STP/MSTP Commands

User’s Manual of FGSD-1022 Series Figure 4-2-19 : SMTP interface The page includes the following fields: Object Description SMTP E-Mail Alarm Allo

Page 182

User’s Manual of FGSD-1022 Series 4.2.10 SNTP It provides the functions allowing the user to update the switch firmware via the Trivial File Transfe

Page 183

User’s Manual of FGSD-1022 Series 6 4.7.2 Static MAC Table...

Page 184

User’s Manual of FGSD-1022 Series Figure 4-2-21 : System Log interface The page includes the following fields: Object Description System Log Mode

Page 185

User’s Manual of FGSD-1022 Series 4.3 Port Configuration Use the Port Configuration Menu to display or configure the Managed Switch’s ports. This sect

Page 186

User’s Manual of FGSD-1022 Series Speed It is available for selecting when the Negotiation column is set as Force. When the Negotiation column is set

Page 187

User’s Manual of FGSD-1022 Series 4.3.2 Rate Control This page provides rate control on each port - it contains Ingress and Egress items and the unit

Page 188 - 6.13 SNMP

User’s Manual of FGSD-1022 Series 4.3.3 Port Status This page displays current port configurations and operating status – it is a ports’ configuration

Page 189 - 6.13.3 Trap Managers

User’s Manual of FGSD-1022 Series 65 The page includes the following fields: Object Description Port: The port number. Description Shows port descri

Page 190 - 6.14 IGMP

User’s Manual of FGSD-1022 Series 4.3.5 Port Sniffer The Port Sniffer (mirroring) is a method for monitor traffic in switched networks. Traffic throug

Page 191

User’s Manual of FGSD-1022 Series Figure 4-3-6: Port Sniffer interface The page includes the following fields: Object Description Sniffer Type: Sel

Page 192 - 6.15 802.1x Protocol

User’s Manual of FGSD-1022 Series 4.3.6 Protect Port There are two protected port groups; ports in different groups can’t communicate. In the same gro

Page 193

User’s Manual of FGSD-1022 Series 4.3.7 Remote Ping The Remote Ping allows user to check the device connection status via ping. Figure 4-3-8: Remote

Page 194

User’s Manual of FGSD-1022 Series 7 6.3.1 Port Configuration and show status ...

Page 195 - 6.16 Access Control List

User’s Manual of FGSD-1022 Series 4.4 VLAN configuration 4.4.1 VLAN Overview A Virtual Local Area Network (VLAN) is a network topology configured ac

Page 196

User’s Manual of FGSD-1022 Series VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between statio

Page 197 - 6.16.2 Non-Ipv4 ACL commands

User’s Manual of FGSD-1022 Series Adding an IEEE802.1Q Tag 72 Dest. Addr. Src. Addr. Length/E. type Data Old CRC Dest. Addr. Src. Addr. E. typ

Page 198 - 6.17 Binding

User’s Manual of FGSD-1022 Series 4.4.2 Static VLAN Configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain

Page 199

User’s Manual of FGSD-1022 Series 4.4.3 Port-based VLAN Packets can go among only members of the same VLAN group. Note all unselected ports are treate

Page 200

User’s Manual of FGSD-1022 Series By adding ports to the VLAN you have created one port-based VLAN group completely. Figure 4-4-3: Static VLAN inte

Page 201

User’s Manual of FGSD-1022 Series 76 4.4.4 802.1Q VLAN Tagged-based VLAN is an IEEE 802.1Q specification standard. Therefore, it is possible to create

Page 202

User’s Manual of FGSD-1022 Series 4.4.4.1 VLAN Group Configuration  VLAN Group Configuration Figure 4-4-4: VLAN Group Configuration interface 1.

Page 203

User’s Manual of FGSD-1022 Series Figure 4-4-5: VLAN Group Configuration interface 5. Select specific port as member port and the screen in Figure

Page 204

User’s Manual of FGSD-1022 Series Figure 4-4-6: 802.1Q VLAN Setting Web Page screen The page includes the following fields: Object Description VLAN

Page 205

User’s Manual of FGSD-1022 Series 8 6.18.1 Display System PoE status ...

Page 206

User’s Manual of FGSD-1022 Series 4.4.4.2 VLAN Filter  802.1Q VLAN Port Configuration This page is used for configuring the Switch port VLAN. The VL

Page 207

User’s Manual of FGSD-1022 Series The VLAN ID must as same as the VLAN ID that the port belong to VLAN group, or the untagged traffic will be dropped.

Page 208 - 6.18.4 Configure PoE -- Port

User’s Manual of FGSD-1022 Series The Managed Switch supports multiple VLAN tags and can therefore be used in MAN applications as a provider bridge, a

Page 209 - (config)# poe priority low 1

User’s Manual of FGSD-1022 Series 83 The page includes the following fields: Object Description Enable: Sets the Managed Switch to QinQ mode, and

Page 210

User’s Manual of FGSD-1022 Series 4.4.5.2 Q-in-Q Tunnel Setting Business customers of service providers often have specific requirements for VLAN IDs

Page 211

User’s Manual of FGSD-1022 Series 4.4.6 GVRP VLAN GVRP (GARP VLAN Registration Protocol or Generic VLAN Registration Protocol) is a protocol that faci

Page 212 - 6.19 SMTP Commands

User’s Manual of FGSD-1022 Series 4.4.6.1 GVRP Setting To configure GVRP Enable global GVRP function: select GVRP enable “Enable”. Enable port GVRP

Page 213

User’s Manual of FGSD-1022 Series 4.4.6.2 GVRP Table The GVRP Table can be used to display dynamic VLANs from being learned via GVRP. Figure 4-4-1

Page 214 - 7. SWITCH OPERATION

User’s Manual of FGSD-1022 Series 88 4.5 Spanning Tree Protocol 4.5.1 Theory The Spanning Tree protocol can be used to detect and disable network loo

Page 215 - 7.5 Auto-Negotiation

User’s Manual of FGSD-1022 Series 89 Bridge Protocol Data Units For STP to arrive at a stable network topology, the following information is used: 

Page 216 - What is PoE?

User’s Manual of FGSD-1022 Series 9 1. Introduction The PLANET Layer 2 Managed Switch series - FGSD-1022, FGSD-1022P and FGSD-1022HP are multiple 10

Page 217

User’s Manual of FGSD-1022 Series Each port on a switch using STP exists is in one of the following five states:  Blocking – the port is blocked fro

Page 218 - The PoE Provision Process

User’s Manual of FGSD-1022 Series 4.5.2 Illustration of STP A simple illustration of three switches connected in a loop is depicted in the below diagr

Page 219 - Operation

User’s Manual of FGSD-1022 Series Figure 4-5-3: After Applying the STA Rules 4.5.3 STP Parameters STP Operation Levels The Switch allows for two le

Page 220 - 9. TROUBLE SHOOTING

User’s Manual of FGSD-1022 Series Priority A relative priority for each switch – lower numbers give a higher priority and a greater chance of a given

Page 221

User’s Manual of FGSD-1022 Series Observe the following formulas when setting the above parameters: Max. Age _ 2 x (Forward Delay – 1 second) Max. Ag

Page 222

User’s Manual of FGSD-1022 Series Max Age (6-40): The number of seconds a switch waits without receiving Spanning-tree Protocol configuration messages

Page 223 - 12345678

User’s Manual of FGSD-1022 Series 96 The page includes the following fields: Object Description  Priority The bridge identifier of the root bridge

Page 224 - EC Declaration of Conformity

User’s Manual of FGSD-1022 Series 4.5.5 Port Configuration This web page provides the port configuration interface for STP. You can assign higher or l

Page 225

User’s Manual of FGSD-1022 Series Admin P2P: The rapid state transitions possible within STP are dependent upon whether the port concerned can only be

Page 226

User’s Manual of FGSD-1022 Series 4.6 Trunking Port trunking is the combination of several ports or network cables to expand the connection speed beyo

Related models: FGSD-1022HP | FGSD-1022P |

Comments to this Manuals

No comments