Summary of Contents

Page 1 - User’s Manual of EPL-2000

User’s Manual of EPL-2000 1

Page 2

User’s Manual of EPL-2000 2. HARDWARE INSTALLATION This section describes the hardware features and installation of the GEPON OLT on the desktop or r

Page 3 - TABLE OF CONTENTS

User’s Manual of EPL-2000 Gigabit SFP PON Slots 1000BASE-PX20 mini-GBIC slot, SFP (Small Form Factor Pluggable) transceiver module: up to 20 kilom

Page 4

User’s Manual of EPL-2000 2.1.3 OLT Rear Panel The rear panel of the GEPON OLT indicates an AC inlet power socket, which accepts input power from 100

Page 5 - 1. INTRODUCTION

User’s Manual of EPL-2000 Figure 2-4 Attaching Brackets to the GEPON OLT. You must use the screws supplied with the mounting brackets. Damage cau

Page 6 - 1.2 Product Description

User’s Manual of EPL-2000 2.2.2 Installing the SFP Transceiver The sections describe how to insert an SFP transceiver into an SFP slot. The SFP trans

Page 7 - 1.4 Product Features

User’s Manual of EPL-2000 1. Make sure both sides of the SFP transceiver are with the same media type, for example: 1000BASE-SX to 1000BASE-SX, 1000

Page 8

User’s Manual of EPL-2000 3. MANAGEMENT SOFTWARE INSTALLATION This chapter explains the methods that you can use to configure management access to th

Page 9 - 1.5 Product Specifications

User’s Manual of EPL-2000 3.2 Management Access Overview The GEPON OLT EPL-2000 supports 10/100Mbps Management interface and two 1000BASE-X net inter

Page 10 - 2. HARDWARE INSTALLATION

User’s Manual of EPL-2000 3.3.1 MySQL Server Installation 1. Please visit MySQL official website http://dev.mysql.com/ and download MySQL-Essential-

Page 11 - 2.1.2 LED Indications

User’s Manual of EPL-2000 4. When the Ready to Install the Program window appears, please click “Install” button. Figure 3-4 Begin Installation W

Page 12 - 2.2 Installing the OLT

User’s Manual of EPL-2000 Trademarks Copyright © PLANET Technology Corp. 2014. Contents are subject to revision without prior notice. PLANET is a r

Page 13

User’s Manual of EPL-2000 6. The “Wizard Completed” window appears, and it will ask for Configure the MySQL server and Register the MySQL Server now

Page 14

User’s Manual of EPL-2000 8. The MySQL Server Instance Configuration window appears; keep the default setting of “Detailed Configuration” and click

Page 15

User’s Manual of EPL-2000 10. Please select the database usage. Keep the default setting of “Multifunctional Database” and click “Next” button. Fig

Page 16 - 3.1 Requirements

User’s Manual of EPL-2000 12. Please set the approximate number of concurrent connections. Keep the default setting of “Decision Support (DSS)/OLAP“

Page 17 - 3.3 EMS Utility Management

User’s Manual of EPL-2000 14. Please select the default character set. Keep the default setting of “Standard Character Set” and click “Next” button.

Page 18

User’s Manual of EPL-2000 16. Please set the security options. Type the password “1234” for current root and new root. Click “Next” button. Figure

Page 19

User’s Manual of EPL-2000 18. Please give a check to “Configuration file created”, “Windows service MySQL installed”, “Service started successfully”

Page 20

User’s Manual of EPL-2000 3.3.2 EMS Utility Installation 1. Insert the bundled CD disk into the CD-ROM drive to launch the autorun program. Once com

Page 21

User’s Manual of EPL-2000 4. Click “Install” for starting installation. Figure 3-21 PL-EMS Installation Screen 5. Click “Finish” button for complet

Page 22

User’s Manual of EPL-2000 6. When the PL-EMS is done, two icons -- PL Server and PL Client – will appear on the desktop. 3.3.3 Starting PLANET EM

Page 23

User’s Manual of EPL-2000 TABLE OF CONTENTS 1. INTRODUCTION...

Page 24

User’s Manual of EPL-2000 3. After entering the user name and password, the PL-EMS main screen will appear as in Figure 3-25. Figure 3-25 Main Scre

Page 25

User’s Manual of EPL-2000 4. EMS Management System PLANET GEPON solutions include the OLT EPL-2000 and ONUs -- EPN-102 and EPN-103. The following inf

Page 26

User’s Manual of EPL-2000 4.1 EMS Toolbar The toolbar includes System, Alarm, Config, Performance and Help features which allows users to do advanced

Page 27

User’s Manual of EPL-2000 The popup window includes the following fields: Object Description Language: Allows user to select the language: English a

Page 28

User’s Manual of EPL-2000 4.1.1.3 Database Maintenance Figure 4-5 Database Maintenance screen The popup window includes the following fields: Objec

Page 29

User’s Manual of EPL-2000 The popup window includes the following fields: Object Description : Add New Account : Delete Account : Save Account

Page 30

User’s Manual of EPL-2000 4.1.2.1 Alarm Query The OLT alarms manager works in concert with the ONUs to provide enhanced management capabilities and c

Page 31 - 4. EMS Management System

User’s Manual of EPL-2000 4.1.2.2 Config Trap Rule Figure 4-9 Config Trap Rule screen The popup window includes the following fields: Object Descr

Page 32 - 4.1 EMS Toolbar

User’s Manual of EPL-2000 4.1.2.3 System Log The GEPON EMS system log information is provided here. This window allows you to log the messages happen

Page 33 - 4.1.1.2 MIB Browser

User’s Manual of EPL-2000 4.1.3 Config This feature allows user to configure the Top Tree, EPL-2000, PON Card and ONU property. Figure 4-12 Toolbar

Page 34 - 4.1.1.4 User Manage

User’s Manual of EPL-2000 4.2.2 Basic Information...

Page 35 - 4.1.2 Alarm:

User’s Manual of EPL-2000 4.1.4 Performance This performance function helps user to verify the OLT connection. This window allows user to issue ICMP

Page 36 - 4.1.2.1 Alarm Query

User’s Manual of EPL-2000 Figure 4-15 Language Screen Figure 4-16 About Screen The popup window includes the following fields: Object Description

Page 37 - 4.1.2.2 Config Trap Rule

User’s Manual of EPL-2000 4.2 OLT Management To manage EPL-2000, EMS manager needs to add EPL-2000 device. They can add and manage the EPL-2000 from

Page 38 - 4.1.2.4 Trap Window

User’s Manual of EPL-2000  For example, add EPL-2000 through Management Port connection Please enter the EPL-2000 default IP address “192.168.1.10”

Page 39 - 4.1.3 Config

User’s Manual of EPL-2000 Figure 4-20 EPL-2000 OLT Management Screen 4.2.1 System Basic Information The Basic System Information page provides info

Page 40 - 4.1.5 Help

User’s Manual of EPL-2000 4.2.2 Basic Information The Basic System Info page provides information for the current device information. Basic System In

Page 41

User’s Manual of EPL-2000 4.2.3 Net Interface Management The system supports two Management IP ports: One is in-band IP and one is out-band IP port

Page 42 - 4.2 OLT Management

User’s Manual of EPL-2000 4.2.4 User Manage This Page provides an overview of the current users. Currently the only way to login as another user on t

Page 43

User’s Manual of EPL-2000 Figure 4-25 User Manage Screen The window includes the following fields: Object Description User Name: The name identifyi

Page 44

User’s Manual of EPL-2000 The window includes the following fields: Object Description IgmpMode: Allows user to select IGMP mode. Robustness: Allows

Page 45 - 4.2.2 Basic Information

User’s Manual of EPL-2000 1. INTRODUCTION PLANET GEPON OLT – EPL-2000 – is GEPON Optical Line Terminal (OLT), consisting of two GEPON ports, two Giga

Page 46

User’s Manual of EPL-2000 Figure 4-27 Trunk Management Screen The window includes the following fields: Object Description Up Trunk: Enable: Trunk

Page 47 - 4.2.4 User Manage

User’s Manual of EPL-2000 in packet headers.  The tagging feature allows VLAN to span multiple 802.1Q-compliant switches through a single physica

Page 48 - 4.2.5 IGMPSetting

User’s Manual of EPL-2000 Port VLAN ID Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compli

Page 49 - 4.2.6 Trunk Management

User’s Manual of EPL-2000  Tagged: Ports with tagging enabled will put the VID number, priority and other VLAN information into the header of all p

Page 50 - 4.2.7 VLAN Management

User’s Manual of EPL-2000 Figure 4-28 VLAN Management Screen The window includes the following fields: Object Description VLAN ID: Indicates the I

Page 51

User’s Manual of EPL-2000 Figure 4-29 Port Property Screen The window includes the following fields: Object Description Port ID: This is the logic

Page 52

User’s Manual of EPL-2000 4.2.8 IPTV Profile This page allows user to create IPTV profile. Figure 4-30 IPTV Profile Screen The window includes the

Page 53 - 4.2.7.2 VLAN Configuration

User’s Manual of EPL-2000 Figure 4-31 IPTV Channel Screen The window includes the following fields: Object Description IPTV Profile: The user can

Page 54

User’s Manual of EPL-2000 Figure 4-32 Port Property Screen The popup window includes the following fields: Object Description Port ID: This is th

Page 55

User’s Manual of EPL-2000 By default, ingress filtering is disabled (no checkmark). Permit Frame Type: Determines whether the port accepts all frames

Page 56 - 4.2.9 IPTV Channel

User’s Manual of EPL-2000 1.2 Product Description Perfectly Designed for FTTx Applications PLANET EPL-2000 is a GEPON Optical Line Terminal (OLT), co

Page 57 - 4.2.10 Port Property

User’s Manual of EPL-2000 4.2.11 Port Status This page displays current port configurations and operating status – it is a ports’ configurations

Page 58

User’s Manual of EPL-2000 4.3 PON Card Management Double-click the PON Card device node unit in the topology tree or right-click PON Card Management

Page 59

User’s Manual of EPL-2000 The popup window includes the following fields: Object Description PON1 Interface Config: PON MAC: Shows the PON1 interfac

Page 60 - 4.2.11 Port Status

User’s Manual of EPL-2000 4.3.2 OLT Global Setting Figure 4-36 OLT Global Setting Screen The popup window includes the following fields: Object De

Page 61 - 4.3 PON Card Management

User’s Manual of EPL-2000 4.3.3 ONU Auth Figure 4-37 Onu Auth Screen The popup window includes the following fields: Object Description PON Port:

Page 62

User’s Manual of EPL-2000 4.4 ONU Management Double-click the EPL-2000 device node unit in the topology tree or right-click Chassis Management in the

Page 63 - 4.3.2 OLT Global Setting

User’s Manual of EPL-2000 4.4.1 Basic Configuration The Basic System page provides information on the current device status. Basic System page helps

Page 64 - 4.3.3 ONU Auth

User’s Manual of EPL-2000 Uni Number: Displays the ONU Uni unmber. Mgt Oam: Displays the ONU OAM management type. CTC Version: Displays the CTC versi

Page 65 - 4.4 ONU Management

User’s Manual of EPL-2000 4.4.3 ONU Multicast Group This page displays all of your multicast connection information. Figure 4-42 Global Parameter Sc

Page 66 - 4.4.1 Basic Configuration

User’s Manual of EPL-2000 Figure 4-43 ONU Port Management Screen The window includes the following fields: Object Description Port: ONU Port1: 10/

Page 67 - 4.4.2 Global Parameter

User’s Manual of EPL-2000 Robust Layer 2 Features With a high-split ratio of 1:64 and supporting the usage of PLANET ONUs, the EPL-2000 can minimize

Page 68 - 4.4.4 ONU Port Management

User’s Manual of EPL-2000 4.4.5 Port Multicast Figure 4-44 ONU Bridging Mode Screen The window includes the following fields: Object Description P

Page 69

User’s Manual of EPL-2000 Figure 4-45 MAC Address Management Screen The window includes the following fields: Object Description Port ID : ONU Por

Page 70 - 4.4.6 ONU VLAN

User’s Manual of EPL-2000 4.4.7 Port Policying This page allows user to modify the Port Policy configuration. Figure 4-46 Port Policying Screen Th

Page 71

User’s Manual of EPL-2000 4.4.8 Port Egress This page allows user to modify the Port Egress configuration. Figure 4-47 Port Egress Screen The wi

Page 72 - 4.4.7 Port Policying

User’s Manual of EPL-2000 4.5 How to upgrade EPL-2000 firmware For upgrading the EPL-2000 firmware, you need to have FTP server software. Here we are

Page 73 - 4.4.8 Port Egress

User’s Manual of EPL-2000 3. Excute “Start Server” for making connection establish. 4. Copy the EPL-2000 firmware to the Home Ftp server directory

Page 74

User’s Manual of EPL-2000 6. After executing the Device Upgrade, the following window will appear. Please fill in the user name and password as “user

Page 75

User’s Manual of EPL-2000 9. Press “Upgrade” button for upgrading the firmware. During the period, the Progress Status will show “Upgrading”. After f

Page 76

User’s Manual of EPL-2000 5. EPL-2000 OPERATION 5.1 Address Table The OLT switch is implemented with an address table. This address table os composed

Page 77

User’s Manual of EPL-2000 APPENDIX A A.1 Switch's RJ45 Pin Assignments 1000Mbps, 1000BASE-T Contact MDI MDI-X 1 BI_DA+ BI_DB+ 2 BI_DA- BI_DB-

Page 78 - 5. EPL-2000 OPERATION

User’s Manual of EPL-2000  Layer 2 Features  Dynamic bandwidth allocation (DBA) support  Supports VLAN - IEEE 802.1Q tagged VLAN - Up to 255

Page 79 - APPENDIX A

User’s Manual of EPL-2000 80 The standard cable, RJ45 pin assignment The standard RJ45 receptacle/connector There are 8 wires on a standard UTP/

Page 80

PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan

Page 81 - EC Declaration of Conformity

User’s Manual of EPL-2000 1.5 Product Specifications Product EPL-2000 Hardware Specifications Transmission Speed Downstream: 1.25 Gbps Upstream:

Comments to this Manuals